SERVICE & MAINTENANCE
Changing the rope grab system
If unsure of any of these steps, contact
ActSafe Systems AB or local distributor.
1. Unscrew the loop inside the textile bag
(2 nuts).
2. Remove the loop, knife and the rope cover
which is mounted on the loop.
3. Unscrew the rope grab and take it o
(5 screws).
4. If necessary change the textile dust pro-
tector (not shown) behind the rope grab.
After cleaning, lubricate the gear ring and
gear wheel with water-proof grease.
5. Replace the rope grab and tighten the
screws to 10 Nm and use Loctite 243.
6. Replace the knife and the loop and
fasten the two M6 nuts with Nordlock
washers at 10 Nm. Make sure the Nord-
lock washers are assembled correctly.
This service must only be performed by
ActSafe or an authorized ActSafe distributor.
DANGER